Setting up the SQ-1 with the MS-20MUpdated 4 months ago
1) Use the 1/8" patch cables and 1/4" patch cables included with the MS-20M to connect the SQ-1 and the MS-20M as shown in the illustration above:
• SQ-1's CV-A OUT jack -> MS-20M's JUNCTION jack -> VCO 1+2 CV IN (V/Oct) jack
• SQ-1's CV-A GATE jack -> MS-20M's JUNCTION jack -> TRIG IN +5V~+15V jack
The MS-20M has two types of TRIG IN jacks, when connecting with the SQ1 you should connect the TRIG IN +5V~+15V jack as when using the SQ-1's factory settings.
2) Set the SQ-1's CV A RANGE setting to 5V. This widens the pitch range you can adjust using the SQ-1's knobs:
• While holding down the SQ-1's FUNCTION button, press the 5V button for the CV A RANGE setting of channel A, making the button light.
3) Press the SQ-1's START/STOP button to trigger the MS-20M.